Добрый день Хабаровчане, нужен совет "бывалых". Вот результат S.M.A.R.T теста
Seagate Barracuda 3TB
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.14 (AF)
Device Model: ST3000DM001-1CH166
Serial Number: W1F1NZTD
LU WWN Device Id: 5 000c50 05cf4a94d
Firmware Version: CC24
User Capacity: 3 000 592 982 016 bytes [3,00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Mon Aug 17 19:35:45 2015 YEKT
==> WARNING: A firmware update for this drive may be available,
see the following Seagate web pages:
http://knowledge.seagate.com/articles/en_US/FAQ/207931en
http://knowledge.seagate.com/articles/en_US/FAQ/223651en
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 584) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 339) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x3085) SCT Status supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 107 099 006 Pre-fail Always - 199747385
3 Spin_Up_Time 0x0003 095 095 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 39
5 Reallocated_Sector_Ct 0x0033 095 095 010 Pre-fail Always - 6000
7 Seek_Error_Rate 0x000f 066 046 030 Pre-fail Always - 141878034147
9 Power_On_Hours 0x0032 078 078 000 Old_age Always - 19754
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 39
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
184 End-to-End_Error 0x0032 098 098 099 Old_age Always FAILING_NOW 2
187 Reported_Uncorrect 0x0032 099 099 000 Old_age Always - 1
188 Command_Timeout 0x0032 100 099 000 Old_age Always - 0 0 1
189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
190 Airflow_Temperature_Cel 0x0022 063 048 045 Old_age Always - 37 (Min/Max 35/37)
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 38
193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 53
194 Temperature_Celsius 0x0022 037 052 000 Old_age Always - 37 (0 22 0 0 0)
197 Current_Pending_Sector 0x0012 089 089 000 Old_age Always - 1816
198 Offline_Uncorrectable 0x0010 089 089 000 Old_age Offline - 1816
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 2
240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 19754h+44m+41.830s
241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 19901927152
242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 32992058876
SMART Error Log Version: 1
ATA Error Count: 1
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 1 occurred at disk power-on lifetime: 19742 hours (822 days + 14 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 ff ff ff 0f Error: WP at LBA = 0x0fffffff = 268435455
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
61 00 08 ff ff ff 4f 00 15d+02:17:05.116 WRITE FPDMA QUEUED
61 00 08 ff ff ff 4f 00 15d+02:17:05.116 WRITE FPDMA QUEUED
61 00 10 ff ff ff 4f 00 15d+02:17:04.529 WRITE FPDMA QUEUED
60 00 08 ff ff ff 4f 00 15d+02:17:03.115 READ FPDMA QUEUED
60 00 08 ff ff ff 4f 00 15d+02:17:00.391 READ FPDMA QUEUED
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Мои "нубские" знания системного администрирования говорят, что пора делать бэкап и менять жесткий диск.
Вопросы:
1) Нужно ли менять жесткий диск?
2) Какой жесткий диск посоветуете (1ТБ)?