Задать вопрос

Hdd будет ли жить?

Доброго времени суток, уважаемые.


Есть домашний серв, F16. но не суть. В нем 5 винтов. один из них Seagate Barracuda 7200.12 на 1 TB.

Вот последний отчет смарта:

smartctl 5.42 2011-10-20 r3458 [x86_64-linux-3.1.5-6.fc16.x86_64] (local build)
Copyright © 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.12
Device Model:     ST31000528AS
Serial Number:    9VP8PEDB
LU WWN Device Id: 5 000c50 02717ec5a
Firmware Version: CC38
User Capacity:    1,000,204,886,016 bytes [1.00 TB]
Sector Size:      512 bytes logical/physical
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Mon Dec 26 11:00:01 2011 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART STATUS RETURN: incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (  634) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 183) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x103f) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   117   099   006    Pre-fail  Always       -       160680946
  3 Spin_Up_Time            0x0003   094   094   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       64
  5 Reallocated_Sector_Ct   0x0033   058   058   036    Pre-fail  Always       -       1725
  7 Seek_Error_Rate         0x000f   072   060   030    Pre-fail  Always       -       4311725570
  9 Power_On_Hours          0x0032   092   092   000    Old_age   Always       -       7459
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       32
183 Runtime_Bad_Block       0x0032   100   100   000    Old_age   Always       -       0
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
188 Command_Timeout         0x0032   100   100   000    Old_age   Always       -       1
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   079   051   045    Old_age   Always       -       21 (Min/Max 10/29)
194 Temperature_Celsius     0x0022   021   049   000    Old_age   Always       -       21 (0 10 0 0 0)
195 Hardware_ECC_Recovered  0x001a   030   020   000    Old_age   Always       -       160680946
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
240 Head_Flying_Hours       0x0000   100   253   000    Old_age   Offline      -       31267361922439
241 Total_LBAs_Written      0x0000   100   253   000    Old_age   Offline      -       4283203444
242 Total_LBAs_Read         0x0000   100   253   000    Old_age   Offline      -       3848296669

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%      7294         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.



и архив данных смарта за неделю:

Вопрос: Будет ли жить винт?

Что уже сделал: гугл, вики, форумы. Что дало: критичные показатели не на нуле, но диск все еще пишет что PASSED все тесты.

В последнем столбце отчета смарта, данные как растут, так и убывают (видно в архиве). Единственный показатель который растет — это Reallocated_Sector_Ct.

По форумам пишут, что сигейты в последнем столбце пишут ахинею.

На что ориентироваться? может я зря панику поднимаю? не люблю неожиданности))


Бекапы уже сделал, вопрос стоит в том покупать ли замену, а то ценник на винты пока еще не очень упал…
  • Вопрос задан
  • 7399 просмотров
Подписаться 5 Оценить Комментировать
Решения вопроса 1
Melkij
@Melkij
PostgreSQL DBA
Однозначно дохнет, у меня тоже был такой красавец.
Важных данных доверять нельзя, но по крайней мере до 2730 релокейтов будет жить и, по уверениям seatools, будет абсолютно здоров. При том, действительно нормально читается-пишется. Потом уже seatools всё-таки признает его гарантийным.
Ответ написан
Пригласить эксперта
Ответы на вопрос 2
alexxxst
@alexxxst
Ну… поживет еще немного, но я бы на вашем месте уже заменил его, думаю, он умрет как раз на копировании всех данных с него, если их много. Уже слишком много ошибок…
P.S. Reallocated_Sector_Ct — это вообще количество перемещенных секторов, т.е. «бэдов». Чем больше — тем ближе смерть…
Ответ написан
opium
@opium
Просто люблю качественно работать
у меня все винты сигейт у которых рос Reallocated_Sector_Ct умерли.
Ответ написан