' Visual Basic Script program to reset the DMA status of all ATA drives
' Copyright © 2006 Hans-Georg Michna
' Version 2007-04-04
' Works in Windows XP, probably also in Windows 2000 and NT.
' Does no harm if Windows version is incompatible.
If MsgBox("This program will now reset the DMA status of all ATA drives with Windows drivers." _
& vbNewline & "Windows will redetect the status after the next reboot, therefore this procedure" _
& vbNewline & "should be harmless.", _
vbOkCancel, "Program start message") _
= vbOk Then
RegPath = "HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Class\{4D36E96A-E325-11CE-BFC1-08002BE10318}\"
ValueName1Master = "MasterIdDataChecksum"
ValueName1Slave = "SlaveIdDataChecksum"
ValueName2Master = "UserMasterDeviceTimingModeAllowed"
ValueName2Slave = "UserSlaveDeviceTimingModeAllowed"
ValueName3 = "ResetErrorCountersOnSuccess"
MessageText = "The following ATA channels have been reset:"
MessageTextLen0 = Len(MessageText)
ConsecutiveMisses = 0
Set WshShell = WScript.CreateObject("WScript.Shell")
For i = 0 to 999
RegSubPath = Right("000" & i, 4) & "\"
' Master
Err.Clear
On Error Resume Next
WshShell.RegRead RegPath & RegSubPath & ValueName1Master
errMaster = Err.Number
On Error Goto 0
If errMaster = 0 Then
On Error Resume Next
WshShell.RegDelete RegPath & RegSubPath & ValueName1Master
WshShell.RegDelete RegPath & RegSubPath & ValueName2Master
On Error Goto 0
MessageText = MessageText & vbNewLine & "Master"
End If
' Slave
Err.Clear
On Error Resume Next
WshShell.RegRead RegPath & RegSubPath & ValueName1Slave
errSlave = Err.Number
On Error Goto 0
If errSlave = 0 Then
On Error Resume Next
WshShell.RegDelete RegPath & RegSubPath & ValueName1Slave
WshShell.RegDelete RegPath & RegSubPath & ValueName2Slave
On Error Goto 0
If errMaster = 0 Then
MessageText = MessageText & " and "
Else
MessageText = MessageText & vbNewLine
End If
MessageText = MessageText & "Slave"
End If
If errMaster = 0 Or errSlave = 0 Then
On Error Resume Next
WshShell.RegWrite RegPath & RegSubPath & ValueName3, 1, "REG_DWORD"
On Error Goto 0
ChannelName = "unnamed channel " & Left(RegSubPath, 4)
On Error Resume Next
ChannelName = WshShell.RegRead(RegPath & RegSubPath & "DriverDesc")
On Error Goto 0
MessageText = MessageText & " of " & ChannelName & ";"
ConsecutiveMisses = 0
Else
ConsecutiveMisses = ConsecutiveMisses + 1
If ConsecutiveMisses >= 32 Then Exit For ' Don't search unnecessarily long.
End If
Next ' i
If Len(MessageText) <= MessageTextLen0 Then
MessageText = "No resettable ATA channels with Windows drivers found. Nothing changed."
Else
MessageText = MessageText & vbNewline _
& "Please reboot now to reset and redetect the DMA status."
End If
MsgBox MessageText, vbOkOnly, "Program finished normally"
End If ' MsgBox(...) = vbOk
' End of Visual Basic Script program
не существует ли софта
Может быть можно обойтись просто установкой на этот ноутбук windows 7 64 bit?
Диск разметился
и судя по всему форматнулся
Главный критерий - надежность девайса.
Современные жесткие диски не предназначены для хранения информации