com.westbyte.downloadmaster.exe
com.westbyte.downloadmaster.json
com.westbyte.downloadmaster.ff.json
Windows Fundamentals for Legacy PCs is not a general-purpose operating system. It is designed to work with the Microsoft Remote Desktop Connection client or third-party clients such as the Citrix ICA client. In addition, it allows for a limited number of workloads to be executed locally, including security software, management software, terminal emulation software, document viewers, and the .NET Framework.
Windows Fundamentals for Legacy PCs (WinFLP) requires:
# A minimum of 611 MB of free hard drive space. Actual requirements will vary based on your system configuration and the applications and features you choose to install. Installing all optional components requires 1151 MB of disk space. These requirements are reported on the screen as you select options in the Setup wizard. Additional hard disk space may be required if you are installing over a network. Also, you should reserve additional space for future updates and service packs.
# A computer with 233 megahertz or higher processor clock speed (300 MHz is recommended); Intel Pentium/Celeron family, or AMD K6/Athlon/Duron family, or compatible processor is recommended.
# 64 MB of RAM. 256 MB of RAM is recommended.
Клавиатура(USB) начинает работать только после загрузки Windows
То есть загрузить предыдущий профиль или сбросить до заводских настроек , но я не могу выбрать сбросить до заводских так как не работает клавиатура . Замкнутый круг!
' Visual Basic Script program to reset the DMA status of all ATA drives
' Copyright © 2006 Hans-Georg Michna
' Version 2007-04-04
' Works in Windows XP, probably also in Windows 2000 and NT.
' Does no harm if Windows version is incompatible.
If MsgBox("This program will now reset the DMA status of all ATA drives with Windows drivers." _
& vbNewline & "Windows will redetect the status after the next reboot, therefore this procedure" _
& vbNewline & "should be harmless.", _
vbOkCancel, "Program start message") _
= vbOk Then
RegPath = "HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Class\{4D36E96A-E325-11CE-BFC1-08002BE10318}\"
ValueName1Master = "MasterIdDataChecksum"
ValueName1Slave = "SlaveIdDataChecksum"
ValueName2Master = "UserMasterDeviceTimingModeAllowed"
ValueName2Slave = "UserSlaveDeviceTimingModeAllowed"
ValueName3 = "ResetErrorCountersOnSuccess"
MessageText = "The following ATA channels have been reset:"
MessageTextLen0 = Len(MessageText)
ConsecutiveMisses = 0
Set WshShell = WScript.CreateObject("WScript.Shell")
For i = 0 to 999
RegSubPath = Right("000" & i, 4) & "\"
' Master
Err.Clear
On Error Resume Next
WshShell.RegRead RegPath & RegSubPath & ValueName1Master
errMaster = Err.Number
On Error Goto 0
If errMaster = 0 Then
On Error Resume Next
WshShell.RegDelete RegPath & RegSubPath & ValueName1Master
WshShell.RegDelete RegPath & RegSubPath & ValueName2Master
On Error Goto 0
MessageText = MessageText & vbNewLine & "Master"
End If
' Slave
Err.Clear
On Error Resume Next
WshShell.RegRead RegPath & RegSubPath & ValueName1Slave
errSlave = Err.Number
On Error Goto 0
If errSlave = 0 Then
On Error Resume Next
WshShell.RegDelete RegPath & RegSubPath & ValueName1Slave
WshShell.RegDelete RegPath & RegSubPath & ValueName2Slave
On Error Goto 0
If errMaster = 0 Then
MessageText = MessageText & " and "
Else
MessageText = MessageText & vbNewLine
End If
MessageText = MessageText & "Slave"
End If
If errMaster = 0 Or errSlave = 0 Then
On Error Resume Next
WshShell.RegWrite RegPath & RegSubPath & ValueName3, 1, "REG_DWORD"
On Error Goto 0
ChannelName = "unnamed channel " & Left(RegSubPath, 4)
On Error Resume Next
ChannelName = WshShell.RegRead(RegPath & RegSubPath & "DriverDesc")
On Error Goto 0
MessageText = MessageText & " of " & ChannelName & ";"
ConsecutiveMisses = 0
Else
ConsecutiveMisses = ConsecutiveMisses + 1
If ConsecutiveMisses >= 32 Then Exit For ' Don't search unnecessarily long.
End If
Next ' i
If Len(MessageText) <= MessageTextLen0 Then
MessageText = "No resettable ATA channels with Windows drivers found. Nothing changed."
Else
MessageText = MessageText & vbNewline _
& "Please reboot now to reset and redetect the DMA status."
End If
MsgBox MessageText, vbOkOnly, "Program finished normally"
End If ' MsgBox(...) = vbOk
' End of Visual Basic Script program