При замене убитого диска через megacli получаю сообщение:
root@debian1:~# megacli -PdReplaceMissing -PhysDrv[252:1] -array0 -row1 -a0
Adapter: 0: Failed to replace Missing PD at Array 0, Row 1.
FW error description:
'PDs in LD have incompatible EEDP types'
Exit Code: 0x63
Пытаюсь включить Protection Information(PI)
root@debian1:~# megacli CfgEachDskRaid0 -enblPI -a0
'PD Doesnt support PI'
Exit Code: 0x01
Как я понимаю, новый диск не поддерживает PI, либо она как-то выключена, не сконфигурирована на нём, а на старых всё включено и они отформатированы с поддержкой PI.
TOPOLOGY :
-----------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR
-----------------------------------------------------------------------------
0 - - - - RAID1 Dgrd N 556.929 GB dsbl Y N dflt N N
0 0 - - - RAID1 Dgrd N 556.929 GB dsbl Y N dflt N N
0 0 0 252:0 13 DRIVE Onln N 278.464 GB dsbl Y N dflt - N
0 0 1 - - DRIVE Msng - 278.464 GB - - - - - N
0 0 2 252:2 11 DRIVE Onln N 278.464 GB dsbl Y N dflt - N
0 0 3 252:3 10 DRIVE Onln N 278.464 GB dsbl Y N dflt - N
-----------------------------------------------------------------------------
У всех дисков видно PI type: 2
root@debian1:~# megacli -PDList -aALL
Adapter #0
Enclosure Device ID: 252
Slot Number: 0
Drive`s position: DiskGroup: 0, Span: 0, Arm: 0
Enclosure position: N/A
Device Id: 13
WWN: 5000C5005A3A75E4
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 279.396 GB [0x22ecb25c Sectors]
Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]
Coerced Size: 278.464 GB [0x22cee000 Sectors]
Sector Size: 512
Firmware state: Online, Spun Up
Commissioned Spare : No
Emergency Spare : No
Device Firmware Level: B55C
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x5000c5005a3a75e5
SAS Address(1): 0x0
Connected Port Number: 3(path0)
Inquiry Data: IBM-ESXSST9300605SS B55C6XP4GY6T0808B55C
IBM FRU/CRU: 90Y8878
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive: Not Certified
Drive Temperature :24C (75.20 F)
'PI Eligibility: Yes
Number of bytes of user data in LBA: 512
Drive is formatted for PI information: Yes
PI: PI with type 2'
Port-0 :
Port status: Active
Port`s Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port`s Linkspeed: 6.0Gb/s
Drive has flagged a S.M.A.R.T alert : No
У нового
Enclosure Device ID: 252
Slot Number: 1
Enclosure position: N/A
Device Id: 14
WWN: 5000C500741861C8
Sequence Number: 1
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 279.396 GB [0x22ecb25c Sectors]
Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]
Coerced Size: 278.464 GB [0x22cee000 Sectors]
Sector Size: 512
Firmware state: Unconfigured(good), Spun Up
Device Firmware Level: B55C
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x5000c500741861c9
SAS Address(1): 0x0
Connected Port Number: 2(path0)
Inquiry Data: IBM-ESXSST9300605SS B55C6XP2GJ8B0808B55C
IBM FRU/CRU: 42D0628
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive: Not Certified
Drive Temperature :25C (77.00 F)
'PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI'
Port-0 :
Port status: Active
Port`s Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port`s Linkspeed: 6.0Gb/s
Drive has flagged a S.M.A.R.T alert : No
Перерыл уже всё, что смог найти, подскажите пожалуйста куда бы дальше покопать?
Как включить PI и заменить диск?