Странные логи в eltex?

Здраствуйте! Подскажи пожалуйста о чем свидетельствует данные логи? Критично ли для организации? И как это исправить?

Коммутатор MES ELTEX 2348P.

244326: Jan 27 08:54:32.697 UTC: %SFF8472-3-THRESHOLD_VIOLATION: Twe1/0/29: Rx power low alarm; Operating value: -23.1 dBm, Threshold value: -23.0 dBm.
244327: Jan 27 08:55:32.053 UTC: %SFF8472-3-THRESHOLD_VIOLATION: Twe2/0/20: Rx power low warning; Operating value: -18.6 dBm, Threshold value: -16.4 dBm.
244328: Jan 27 08:57:47.299 UTC: %SFF8472-3-THRESHOLD_VIOLATION: Twe1/0/20: Rx power low warning; Operating value: -17.2 dBm, Threshold value: -16.4 dBm.

244329: Jan 27 08:58:30.341 UTC: %LINK-3-UPDOWN: Interface TwentyFiveGigE1/0/36, changed state to up
244330: Jan 27 08:58:40.316 UTC: %LINK-3-UPDOWN: Interface TwentyFiveGigE1/0/36, changed state to down
244331: Jan 27 09:01:23.602 UTC: %SFF8472-3-THRESHOLD_VIOLATION: Twe2/0/33: Rx power high warning; Operating value: 0.0 dBm, Threshold value: 0.0 dBm.
244332: Jan 27 09:03:44.338 UTC: %LINK-3-UPDOWN: Interface TwentyFiveGigE1/0/36, changed state to up
244333: Jan 27 09:03:54.307 UTC: %LINK-3-UPDOWN: Interface TwentyFiveGigE1/0/36, changed state to down
244334: Jan 27 09:04:32.805 UTC: %SFF8472-3-THRESHOLD_VIOLATION: Twe1/0/29: Rx power low alarm; Operating value: -23.1 dBm, Threshold value: -23.0 dBm.
244335: Jan 27 09:05:32.193 UTC: %SFF8472-3-THRESHOLD_VIOLATION: Twe2/0/20: Rx power low warning; Operating value: -18.6 dBm, Threshold value: -16.4 dBm.
244336: Jan 27 09:07:47.405 UTC: %SFF8472-3-THRESHOLD_VIOLATION: Twe1/0/20: Rx power low warning; Operating value: -17.2 dBm, Threshold value: -16.4 dBm.

244337: Jan 27 09:08:56.872 UTC: %LINK-3-UPDOWN: Interface TwentyFiveGigE1/0/36, changed state to up
244338: Jan 27 09:09:00.877 UTC: %LINEPROTO-5-UPDOWN: Line protocol on Interface TwentyFiveGigE1/0/36, changed state to up
244339: Jan 27 09:09:05.844 UTC: %LINEPROTO-5-UPDOWN: Line protocol on Interface TwentyFiveGigE1/0/36, changed state to down
244340: Jan 27 09:09:06.850 UTC: %LINK-3-UPDOWN: Interface TwentyFiveGigE1/0/36, changed state to down
244341: Jan 27 09:14:09.415 UTC: %LINK-3-UPDOWN: Interface TwentyFiveGigE1/0/36, changed state to up
244342: Jan 27 09:14:13.709 UTC: %LINEPROTO-5-UPDOWN: Line protocol on Interface TwentyFiveGigE1/0/36, changed state to up
244343: Jan 27 09:14:18.388 UTC: %LINEPROTO-5-UPDOWN: Line protocol on Interface TwentyFiveGigE1/0/36, changed state to down
244344: Jan 27 09:14:19.392 UTC: %LINK-3-UPDOWN: Interface TwentyFiveGigE1/0/36, changed state to down
244345: Jan 27 09:14:32.912 UTC: %SFF8472-3-THRESHOLD_VIOLATION: Twe1/0/29: Rx power low alarm; Operating value: -23.1 dBm, Threshold value: -23.0 dBm.
244346: Jan 27 09:15:32.329 UTC: %SFF8472-3-THRESHOLD_VIOLATION: Twe2/0/20: Rx power low warning; Operating value: -18.6 dBm, Threshold value: -16.4 dBm.
244347: Jan 27 09:17:47.512 UTC: %SFF8472-3-THRESHOLD_VIOLATION: Twe1/0/20: Rx power low warning; Operating value: -17.2 dBm, Threshold value: -16.4 dBm.

244348: Jan 27 09:19:22.076 UTC: %LINK-3-UPDOWN: Interface TwentyFiveGigE1/0/36, changed state to up
244349: Jan 27 09:19:27.054 UTC: %LINEPROTO-5-UPDOWN: Line protocol on Interface TwentyFiveGigE1/0/36, changed state to up
244350: Jan 27 09:19:30.771 UTC: %LINEPROTO-5-UPDOWN: Line protocol on Interface TwentyFiveGigE1/0/36, changed state to down
244351: Jan 27 09:19:32.065 UTC: %LINK-3-UPDOWN: Interface TwentyFiveGigE1/0/36, changed state to down
  • Вопрос задан
  • 132 просмотра
Пригласить эксперта
Ответы на вопрос 2
NeiroNx
@NeiroNx
Программист
на двух портах плохой сигнал. Проверяй коннекторы, сам провод - возможно где то обрыв.
Ответ написан
Комментировать
@4ncy
Низкое качество сигнала по RX, у тебя линк на грани отвала (если уже не отвалился).
Судя по логу, там оптика включена.
У тебя два значения
1) Operating value - сигнал в данный момент
2) Threshold value - сигнал при котором выдается авария
Как видишь, сигнал хуже чем показатель при аварийном состоянии.
Нужно стрелять рефляком на наличие проблем, проверять SFP модуль, либо, если потери сервисов нет, поменять значение Threshold value руками и поставить чуть выше значение.
Ответ написан