git reset --hard 26d726a
HEAD сейчас на 26d726a2 Version 2.4.8
root@mint:~# smartctl --all /dev/sda
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.15.0-56-generic] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Silicon Motion based SSDs
Device Model: ADATA SU650
Serial Number: AA000000000000003924
Firmware Version: S0424A0
User Capacity: 240,057,409,536 bytes [240 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Jan 18 15:22:56 2023 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
No failed Attributes found.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x11) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0002) Does not save SMART data before
entering power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 10) minutes.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0032 100 100 050 Old_age Always - 1
5 Reallocated_Sector_Ct 0x0032 100 100 050 Old_age Always - 44
9 Power_On_Hours 0x0032 100 100 050 Old_age Always - 1014
12 Power_Cycle_Count 0x0032 100 100 050 Old_age Always - 856
160 Uncorrectable_Error_Cnt 0x0032 100 100 050 Old_age Always - 295
161 Valid_Spare_Block_Cnt 0x0033 100 100 050 Pre-fail Always - 2
163 Initial_Bad_Block_Count 0x0032 100 100 050 Old_age Always - 9
164 Total_Erase_Count 0x0032 100 100 050 Old_age Always - 19587
165 Max_Erase_Count 0x0032 100 100 050 Old_age Always - 107
166 Min_Erase_Count 0x0032 100 100 050 Old_age Always - 12
167 Average_Erase_Count 0x0032 100 100 050 Old_age Always - 39
168 Max_Erase_Count_of_Spec 0x0032 100 100 050 Old_age Always - 7000
169 Remaining_Lifetime_Perc 0x0032 100 100 050 Old_age Always - 100
175 Program_Fail_Count_Chip 0x0032 100 100 050 Old_age Always - 0
176 Erase_Fail_Count_Chip 0x0032 100 100 050 Old_age Always - 0
177 Wear_Leveling_Count 0x0032 100 100 050 Old_age Always - 0
178 Runtime_Invalid_Blk_Cnt 0x0032 100 100 050 Old_age Always - 44
181 Program_Fail_Cnt_Total 0x0032 100 100 050 Old_age Always - 0
182 Erase_Fail_Count_Total 0x0032 100 100 050 Old_age Always - 0
192 Power-Off_Retract_Count 0x0032 100 100 050 Old_age Always - 100
194 Temperature_Celsius 0x0022 100 100 050 Old_age Always - 40
195 Hardware_ECC_Recovered 0x0032 100 100 050 Old_age Always - 123673
196 Reallocated_Event_Count 0x0032 100 100 050 Old_age Always - 295
197 Current_Pending_Sector 0x0032 100 100 050 Old_age Always - 44
198 Offline_Uncorrectable 0x0032 100 100 050 Old_age Always - 295
199 UDMA_CRC_Error_Count 0x0032 100 100 050 Old_age Always - 0
232 Available_Reservd_Space 0x0032 100 100 050 Old_age Always - 2
241 Host_Writes_32MiB 0x0030 100 100 050 Old_age Offline - 59012
242 Host_Reads_32MiB 0x0030 100 100 050 Old_age Offline - 45921
245 TLC_Writes_32MiB 0x0032 100 100 050 Old_age Always - 112770
SMART Error Log Version: 1
Warning: ATA error count 0 inconsistent with error log pointer 3
ATA Error Count: 0
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error -4 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
00 00 00 00 00 00 00
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
b0 d0 01 00 4f c2 00 08 00:00:00.000 SMART READ DATA
b0 d1 01 01 4f c2 00 08 00:00:00.000 SMART READ ATTRIBUTE THRESHOLDS [OBS-4]
b0 da 00 00 4f c2 00 08 00:00:00.000 SMART RETURN STATUS
b0 d5 01 00 4f c2 00 08 00:00:00.000 SMART READ LOG
b0 d5 01 01 4f c2 00 08 00:00:00.000 SMART READ LOG
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Aborted by host 60% 1014 -
Selective Self-tests/Logging not supported
PS за наводку спасибо!