interface GigabitEthernet0/0
ip address 192.168.42.254 255.255.255.0
duplex auto
speed auto
!
interface GigabitEthernet1/0
ip address 172.24.0.1 255.255.0.0
duplex auto
speed auto
!
interface GigabitEthernet2/0
ip address 172.31.1.1 255.255.0.0
duplex auto
speed auto
!
router rip
version 2
network 172.24.0.0
network 172.31.0.0
network 192.168.42.0
C 172.24.0.0/16 is directly connected, GigabitEthernet1/0
R 172.26.0.0/16 [120/1] via 172.24.0.2, 00:00:08, GigabitEthernet1/0
[120/1] via 172.31.1.2, 00:00:04, GigabitEthernet2/0
C 172.31.0.0/16 is directly connected, GigabitEthernet2/0
R 192.168.22.0/24 [120/1] via 172.24.0.2, 00:00:08, GigabitEthernet1/0
R 192.168.38.0/24 [120/1] via 172.31.1.2, 00:00:04, GigabitEthernet2/0
C 192.168.42.0/24 is directly connected, GigabitEthernet0/0
/conf t
/router bgp 400
/network 0.0.0.0 mask 0.0.0.0
gateway: 172.31.1.1
Пинги проходят. При обрыве сети между SwM2 и BSBO_09_L, узел bad_man опять теряется, тк gw ведет к отключенному интерфейсу. Однако у него теоретически есть возмодность пинговать всех через узел BSBO_09_B.
Возможно ли реализовать такой механизм, при котором bad_man будет иметь возможность пиновать узлы независимо от работоспособности соединений (имею ввиду, когда одно из соединений до левого или нижнего роутера оборвано)?